The One
Piece Core Wire and Jointless Spring Coil design provide constant
reliability, precision and performance. |
|
| |
Precise Steerability |
|
| |
|
The One Piece Core Wire design enables
excellent tip shaping and helps to maintain tip integrity
throughout the case.
|
|
|
| |
|
|
| |
Smooth Delivery & Access to Lesions |
|
| |
|
The Jointless Spring Coil construction
provides excellent tracking around tight bends. |
|
|
| |
|
|
| |
|
The One Piece Core Wire ensures
powerful performance, even in highly stenosed lesions. |
|
|
| |
|
|
| |
|
Silicone, Fluororesin, and hydrophilic
coatings reduce friction and create a seamless, lubricious
surface. |
|
|
| |
|
|
| |
Excellent Torque Response |
|
| |
|
The unique flat wire design of the
One Piece Core Wire provides an accurate 1:1 response to manipulation
for outstanding tactile feedback and control. |
|
|
| |
|
|
| |
High Radiopacitye |
|
| |
|
Dual stainless steel
platinum construction provides a very visible, radiopaque
tip. |
|
|
| |
|
|
| |
Daily Performance
Wires |
|
| |
|
 |
Radiopacity length: 3cm Outside
diameter : 0.014"
Total length: 180cm, 300cm |
The unique core
design ensures improved lubricity and excellent tip shape-memory.
The high torque response and flexible tip makes this guidewire
a first choice for almost all procedures. (Tip load 0.5g) |
 |
|
|
| |
|
|
| |
|
|
| |
|
 |
Radiopacity length: 3cm Outside
diameter : 0.014"
Total length: 180cm, 300cm |
A first choice guidewire with a high
torque response and excellent steerability owing to the
unique core properties.(Tip load 0.7g)
|
 |
|
|
| |
|
|
| |
|
|
| |
|
 |
Radiopacity
length: 3cm Outside diameter
: 0.014" Total length: 180cm, 300cm |
With a hydrophilic coating over the
spring coil (3cm from the tip) and a newly designed core
shaft, this guidewire offers higher support performance
than SOFT plus improved torque performance. (Tip load 0.8g)
|
 |
|
|
| |
|
|
| |
|
|
| |
Advanced Performance
Wires |
|
| |
|
 |
| Radiopacity
length: 3cm Outside diameter : 0.014" Total length: 180cm,
300cm |
This guidewire provides superb balance
of tip flexibility and support performance. (Tip load 3.0g)
|
 |
|
|
| |
|
|
| |
|
|
| |
|
 |
| Radiopacity
length: 3cm Outside diameter : 0.014" Total length: 180cm,
300cm |
Improved tip
stiffness with our unique core taper design. (Tip load 6.5g) |
 |
|
|
| |
|
|
| |
|
|
| |
Speciality Wires |
|
| |
| Asahi
Grand Slam AG141002 |
|
 |
| Radiopacity
length: 3cm Outside diameter : 0.014" Total length: 180cm,
300cm |
In spite of
its flexible tip, the core is also designed to provide
strong support when approaching tortuous lesions.
(Tip load 0.7g) |
 |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
The patent rights of all these products are with
Abbott Vascular Devices and Biomedicon is just the distributor for
them in India. |
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|