Biodiv
Y sio OC
Coronary
Stent System |
 |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
Mimics the body's own chemistry
The Biodiv Ysio SV Stent is coated with unique
PC Technology™.
PC Technology is a synthetic copy of the outside
surface of a red blood cell which reduces the body's response to
an implanted device.
Water molecules attach themselves to the PC
coating encapsulating the stent in a protective layer. It is this
biological mimicry that makes PC Technology safe, thrombo-resistant
and biologically neutral over the long term.
A powerful change in the tradition of stenting. |
|
| |
 |
|
| |
|
|
| |
| Biodiv
Ysio OC |
the
power to care |

Unique design and laser sculpted
from a 1 mm tube. |
Smaller coronary arteries
pose a significant clinical challenge to physicians. The Biodiv
Ysio SV stent system has unique features that help
increase access to these difficult to reach vessels. Its small,
tailored design combines a performant delivery system with
a wider range of stent diameters.
The HTP system greater "pushability"
and 5Fr guide compatibility for improved access to lesions.
Catheter flexibility eases navigation through even the most
tortuous anatomy. The range of sizes allows you to select
the stent best suited to the patient's needs. |
|
|
| |
Providing
a powerful new means of enhancing patient card. |
|
| |
|
|
| |
| |
|
Balloon
optimally matched to stent lengths for accurate and confident
placement |
| |
|
|
Increased
range of sizes on a 5F compatible delivery system |
| |
|
|
Reduced
crossing profiles designed to traverse the most comples
lesions |
|
|
|
| |
|
|
| |
Order Information: |
|
| |
| Part Number |
Nominal Stent Diameter
(mm) |
Stent Length
(mm) |
Balloon Length
(mm) |
| HTP-08275OC |
2,75 |
8 |
9 |
| HTP-08300OC |
3 |
8 |
9 |
| HTP-08350OC |
3,5 |
8 |
9 |
| HTP-08400OC |
4 |
8 |
9 |
| HTP-18275OC |
2,75 |
18 |
19 |
| HTP-18300OC |
3 |
18 |
19 |
| HTP-18350OC |
3,5 |
18 |
19 |
| HTP-18400OC |
4 |
18 |
19 |
| HTP-28275OC |
2,75 |
28 |
29 |
| HTP-28300OC |
3 |
28 |
29 |
| HTP-28350OC |
3,5 |
28 |
29 |
| HTP-28400OC |
4 |
28 |
29 |
| HTP-11275OC |
2,75 |
11 |
12 |
| HTP-11300OC |
3 |
11 |
12 |
| HTP-11350OC |
3,5 |
11 |
12 |
| HTP-11400OC |
4 |
11 |
12 |
| HTP-15275OC |
2,75 |
15 |
16 |
| HTP-15300OC |
3 |
15 |
16 |
| HTP-15350OC |
3,5 |
15 |
16 |
| HTP-15400OC |
4 |
15 |
16 |
| HTP-22275OC |
2,75 |
22 |
23 |
| HTP-22300OC |
3 |
22 |
23 |
| HTP-22350OC |
3,5 |
22 |
23 |
| HTP-22400OC |
4 |
22 |
23 |
|
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
The patent rights of all these products are with