Product Search
 
 
 
 
 
 
 
 
 
 
Sitemap
 
Links
 
 
     
 
Back
 
     
     
 
 
     
   
     
 
JOCATH Mercury
Out of this world
 
     
 
 
     
     
   JOCATH ® Mercury Compliance Charts  
 
Pressure (bar) Balloon diameter (mm)

1.50

2.00 2.25 2.50 2.75 3.00 3.25 3.50 4.00
 4
1.43
1.91
2.15
2.39
2.63
2.87
3.11
3.34
3.82
 5
1.45
1.93
2.18
2.42
2.66
2.90
3.14
3.38
3.86
 6
1.47
1.96
2.20
2.45
2.69
2.93
3.18
3.42
3.91
 7
1.48
1.98
2.23
2.47
2.72
2.97
3.22
3.46
3.95
 8* 1.50 2.00 2.25 2.50 2.75 3.00 3.25 3.50 4.00
 9 1.52 2.03 2.28 2.53 2.78 3.04 3.29 3.54 4.04
 10 1.53 2.05 2.31 2.56 2.81 3.07 3.33 3.58 4.09
 11 1.55 2.07 2.33 2.59 2.84 3.10 3.36 3.62 4.13
 12 1.57 2.10 2.36 2.61 2.87 3.14 3.40 3.66 4.18
 13 1.59 2.12 2.38 2.64 2.91 3.17 3.44 3.70 4.22
 14 1.60 2.14 2.41 2.67 2.94 3.21 3.48 3.74 4.27
 15 1.62 2.16 2.44 2.70 2.97 3.24 3.51 3.78 4.31
 16** 1.64 2.19 2.46 2.73 3.00 3.27 3.55 3.82 4.36
 17 1.65 2.21 2.49 2.75 3.03 3.31 3.59 3.86 4.40
 18 1.67 2.23 2.51 2.78 3.06 3.34 3.62 3.90 4.45
 19 1.69 2.26 2.54 2.81 3.09 3.38 3.66 3.94 4.49
 20 1.70 2.28 2.57 2.84 3.12 3.41 3.70 3.98 4.54
 * Nominal pressure
 ** Rated burst pressure
 
     
 
 Technical details:
  Balloon Material:
  Balloon Compliance: Semi-compliant
  Shaft Diameter: 2.0F proximal
2.7F distal
  Shaft length: 140-145 cm
  Lesion Entry Profile: < 0.017"
  Nominal Pressure: 8 bar
  Rated Burst Pressure: 16 bar
  Average Burst Pressure: > 22 bar
  Coating: HYDREX Coating System
  Min. Guiding Catheter: 5F (0.058")
 
JOMED brings tomorrows technology here today with our latest PTCA balloon catheter for even the most complex procedures
 
     
   
     
     
  Order Information:  
 

Order Number

Balloon Length Balloon Diameter No. of Radiopaque Markers
M31115 11 mm 1.50 mm 1
M31120 11 mm 2.00 mm 2
M31125 11 mm 2.50 mm 2
M31130 11 mm 3.00 mm 2
M31135 11 mm 3.50 mm 2
M31140 11 mm 4.00 mm 2
M31415 14 mm 1.50 mm 1
M31420 14 mm 2.00 mm 2
M31425 14 mm 2.50 mm 2
M31430 14 mm 3.00 mm 2
M31435 14 mm 3.50 mm 2
M31440 14 mm 4.00 mm 2
M32015 20 mm 1.50 mm 1
M32020 20 mm 2.00 mm 2
M32022 20 mm 2.25 mm 2
M32025 20 mm 2.50 mm 2
M32027 20 mm 2.75 mm 2
M32030 20 mm 3.00 mm 2
M32032 20 mm 3.25 mm 2
M32035 20 mm 3.50 mm 2
M32040 20 mm 4.00 mm 2
 
     
     
 
 
     
     
  The patent rights of all these products are with Abbott Vascular Devices and Biomedicon is just the distributor for them in India.  
     
 