Product Search
 
 
 
 
 
 
 
 
 
 
Sitemap
 
Links
 
 
     
 
Back
 
     
     
 
 
     
 
JOSTENT GraftMaster
With increased Flexibility
 
     
 
 
     
     
 
The JOSTENT®GraftMaster represents the
ONLY choice in Acute Situations such as:
PERFORATIONS
RUPTURES
 
The JOSTENT®GraftMaster is also
beneficial in situations such as:
ANEURYSMS
SAPHENOUS VEIN GRAFTS
FISTULA
 
     
  Unique Design When Stent Placement is Critical.
The Coronary Stent Graft is Mounted DIRECTLY ONTO THE MARKERS.
 
   
   
  Features the latest balloon/shaft technology of the JOCATH Maestro from JOMED. The different shaft segments provide a harmony that balances the delivery system and converts pushability into superior trackability.  
     
 

 Low profile

 
The minimal lesion entry profile of 0.017" combined with the low premounted stent profile gives the JOSTENT®GraftMaster superior crossability. This also facilitates access to distal lesions.
 
 Micro precise placement
GraftMaster is unique in that the stent is positioned ONTO THE MARKERS and the outer edges of the markers denote the end of the stent. When placing the stent between the markers there is often an inconsistency in the marker to stent distance.
 
 Premounted
NO additional crimping! Easy, safe and accurate delivery of the OSTENT®Coronary Stent Graft. The unique folding of the balloon gives uniform expansion of the stent graft. The expansion pressure is 12-14 bar in order to achieve optimal apposition to the vessel wall (see technical information). The use of IVUS is strongly recommended.
 
     
   
 
…has been constructed using a sandwich technique,
 whereby an ultra thin layer of expandable PTFE is
 placed between two JOSTENT®Flex Stents.
 
 
  sandwich technique
 Radial Strength 
The unique Flex design allows the stent to exert
maximum radial strength, whilst being flexible enough
to navigate through tortuous vessels.
 Visibility
The JOSTENT®Coronary Stent Graft has superior
visibility due to its unique sandwich design.
 
 
     
 
Expandable PTFE Graft Material
The PTFE graft material has been specifically developed by JOMED for integrating into a stent graft system. The PTFE material is constructed to allow expansion in one direction, whilst remaining rigid longitudinally.
 
     
     
 
 
     
     
     
     
  The patent rights of all these products are with Abbott Vascular Devices and Biomedicon is just the distributor for them in India.  
     
 
top
 
 
Back
 
     
  Copyright © 2005 Biomedicon Systems Pvt. Ltd. Designed by: vdesign2shine